Sign In | Join Free | My chinaqualitycrafts.com |
|
Brand Name : TBB
Model Number : TP610M-1U
Certification : CE,ISO9000
Place of Origin : China
MOQ : 1piece
Price : Negotiable
Payment Terms : T/T
Delivery Time : 1-3days depends on batch order qty
Packaging Details : Carton, Plywood pallet
Model : TP610M-1U
Capacity : 1000VA
DC INPUT : 48VDC
AC OUPUT : 230VAC/220VAC/120VAC
Frequncy : 50HZ
Installation : Subrack 19"
Weight : 6KG
Hight : 1U
Display : LCD or LED Display
Application : Industrial and Telecom
Architecture: "Stand alone" rackable in 19 ".
- automatic bypass: the equipment must have 110VDC and 220VAC inputs so that in the event of an operational input failure, the equipment transfers load to the alternate input automatically, and the interruption or disturbance in the output must last less than or equal to 10ms.
Combined with modern semiconductors and a patent pending control algorithm, TP600-1U inverter could achieve a compact size within the 19”1U height.
TP600-1U standalone inverter features an integrated utility bypass. With a dip switch, the inverter can be set into AC priority mode, of which power is always connected to the AC utility line and will switch to inverter power line when AC utility fails with transfer time less than 8ms.
LED version - indicators for input voltage range, load power range, normal output & failure state
Industrial grade design
EMC LVD test
Here are the Features;
- 19”1U or 19”2U
- High Frequency standby design with
- Transfer time 5-8ms
- Working mode selectable (AC priority or DC priority)
- High Frequency design
- DC/AC isolation improving system security
- Complete protection
- Thermal controlled fan
- RS232 or RS485 communication port and Dry point
- Voltage adjustable 230Vac (200-240) or 110Vac (100-120)
- Front panel connection version available
- System parameters programmable
LED shows
Specifications
TP600M and TP600S (24VDC/48VDC models)
Model | TP605 | TP610 |
Electrical | ||
DC input | 24Vdc or 48Vdc | 48Vdc |
Dc input range | .-17% ~ +25% | |
AC Input | ||
AC input | 230Vac or 110Vac (-25%~+20%) | 230Vac (-25%~+20%) |
Frequency range | ±10% | |
Output power | 500va | 1kva |
Wave form | Pure sine wave | |
Power factor | 0.8 | |
Norminal output voltage | 230Vac or 110Vac | 230Vac |
Voltage variation | Max ± 2% | |
Output frequency | 50/60Hz ± 0.1Hz | |
Efficiency | Max 88% | |
THD | <3% liner load | |
<5% non-liner load | ||
Crest factor | .3:1 | |
Overload | 125% 10secs | |
110% 10mins | ||
Transfer time | 5-8ms | |
Dynamic response time | < 30ms | |
LVD | 20Vdc or 40Vdc | 40Vdc |
Display & Communication | ||
LED indicator | Working mode, Fault info | |
Communication Interface | RS232 and RS485 | |
4xDry contact | ||
Safety & Enviroment | ||
Operating Temp. | Full load, <-20℃> - 40℃ | |
Derating using, 40℃ - 60℃ | ||
Isolation | 1500Vrms | |
Mechanical | ||
Dimension (WxH) | 19"1U | |
Depth | 319mm | |
Weight | 4.0kgs/4.5kgs | |
Cooling | forced fan with thermal control | |
Enclosure | IP20 | |
Standard | ||
LVD | EN60950-1 | |
EMC | EN55022 |
![]() |